Facile whole mitochondrial genome resequencing from nipple aspirate fluid using MitoChip v2.0
BMC Cancer volume 8, Article number: 95 (2008)
Abstract
Background
Mutations in the mitochondrial genome (mtgenome) have been associated with many disorders, including breast cancer. Nipple aspirate fluid (NAF) from symptomatic women could potentially serve as a minimally invasive sample for breast cancer screening by detecting somatic mutations in this biofluid. This study is aimed at 1) demonstrating the feasibility of NAF recovery from symptomatic women, 2) examining the feasibility of sequencing the entire mitochondrial genome from NAF samples, 3) cross validation of the Human mitochondrial resequencing array 2.0 (MCv2), and 4) assessing the somatic mtDNA mutation rate in benign breast diseases as a potential tool for monitoring early somatic mutations associated with breast cancer.
Methods
NAF and blood were obtained from women with symptomatic benign breast conditions, and we successfully assessed the mutation load in the entire mitochondrial genome of 19 of these women. DNA extracts from NAF were sequenced using the mitochondrial resequencing array MCv2 and by capillary electrophoresis (CE) methods as a quality comparison. Sequencing was performed independently at two institutions and the results compared. The germline mtDNA sequence determined using DNA isolated from the patient's blood (control) was compared to the mutations present in cellular mtDNA recovered from patient's NAF.
Results
From the cohort of 28 women recruited for this study, NAF was successfully recovered from 23 participants (82%). Twenty two (96%) of the women produced fluids from both breasts. Twenty NAF samples and corresponding blood were chosen for this study. Except for one NAF sample, the whole mtgenome was successfully amplified using a single primer pair, or three pairs of overlapping primers. Comparison of MCv2 data from the two institutions demonstrates 99.200% concordance. Moreover, MCv2 data was 99.999% identical to CE sequencing, indicating that MCv2 is a reliable method to rapidly sequence the entire mtgenome. Four NAF samples contained somatic mutations.
Conclusion
We have demonstrated that NAF is a suitable material for mtDNA sequence analysis using the rapid and reliable MCv2. Somatic mtDNA mutations present in NAF of women with benign breast diseases could potentially be used as risk factors for progression to breast cancer, but this will require a much larger study with clinical follow up.
Background
The increased number of cancer cases around the world is a major concern. Research methods for identifying the presence of cancerous cells by measuring mutations in mtDNA is the subject of intense clinical investigation [1, 2]. Frequently, these studies analyze only specific regions of mtDNA and not the entire mitochondrial genome (mtgenome). There are several biological characteristics of mitochondria, and in particular the mtgenome that make it suitable for early detection and monitoring of neoplasia. This genome has an accelerated mutation rate in comparison to the nuclear genome and accrues somatic mutations in tumor tissues [2–5]. The mitochondrial genome has a high copy number in comparison to the nuclear archive of DNA; there are potentially 1,000s of mtgenomes per cell, which enables easy detection of important biomarkers, even when only low amounts of samples are available.
Given its small size and vital role in bioenergetics, the mtgenome is frequently sequenced in its entirety [1, 2, 6]. MtDNA mutations increase the risk of mitochondrial associated diseases later in life [7]. Here we report the feasibility of sequencing the complete mtgenome from nipple aspirate fluid (NAF), and the reliability of microarray based resequencing of the mtgenome to CE sequencing technology as well as the reproducibility of the resequencing methodology in a cross validation study between the National Institute of Standards and Technology (Gaithersburg, MD USA) and Genesis Genomics Inc. (Thunder Bay, On Canada). This study also uncovered mtgenome mutations in NAF, a relatively easily obtained body fluid, which has potential use for early breast cancer detection, diagnosis and monitoring [8].
Dr. Susan Love pioneered the intraductal approach to access the lobular units where breast cancer begins [9]. NAF can be recovered from 48% to 94% of women and represents a minimally invasive technique for obtaining breast fluids for the evaluation of abnormalities associated with breast cancer [10–14]. NAF production has been linked to an increased relative risk for breast cancer development [15], and the evaluation of NAF as a potential screening tool for the detection of breast cancer has been the subject of intense investigation [16–18]. NAF from women with no clinical evidence of breast tumors has also been analyzed to detect mtDNA mutations and for genetic variants (BRACA1) that are associated with breast cancer development [19].
A limitation of using NAF for diagnosis has been the sensitivity of detection technologies. However, with recently developed technologies and modern sensitive cancer biomarkers [20], the usefulness of NAF deserves re-evaluation. An important limitation of the use of NAF is its low cellular content, which often precludes histopathologic analyses [12]; however, analyses of predictive markers in this biofluid can identify the presence of cancer [21]. Ductal lavage is a technique designed to overcome low cellularity and allows access to an entire duct system. This procedure results in high cytological/histological specificity (100%), but low sensitivity and accuracy (17% and 19% respectively) [22]. The analysis of NAF to monitor recurrence may have limited application, because risk reduction therapies, including selective estrogen receptor modulators (tamoxifen, raloxifene or oophorectomy), appear to reduce NAF yields [15].
The high copy number of the mtgenomes [23] is an advantage of using mtDNA SNP analysis for early detection and monitoring disease progression. In addition, rapid, accurate and relatively low cost resequencing methods streamline mutation detection and justify complete mtgenome analysis of cancer associated mutations in tumor and preneoplastic tissues. Sequencing the entire mtgenome allows for a complete inventory of the point mutations in this genome that may develop in association with disease pathology and provide early detection markers [1].
Herein we report the utility of NAF for rapid whole mtgenome analysis. This study represents the largest number of NAF samples sequenced, and the first application of DNA microarray measurement of the mutation load in NAF. The results were independently cross-validated. Microarray analysis has an increased sensitivity over fluorescent sequencing [24]. We detected somatic mutations in NAF that were not present in the matched control tissue. While our study does not answer the etiology behind mutations present in NAF, our findings suggest that this paradigm may be useful for screening NAF for mtDNA mutations analogous to recent clinical proposals [25].
Methods
Study Subjects
Symptomatic women referred to a surgical oncologist for a clinical breast examination and who had a negative result were recruited for this study. A total of 20 women were selected for the cross validation study. All patients were recruited in accordance with the ethical guidelines of the Thunder Bay Regional Health Sciences Ethics Board in adherence to the Tri-Council Policy Statement on Ethical Conduct for Research Involving Humans. Written consent was obtained from the patients for publication of the study.
Samples
Blood samples were collected by standard venipuncture using a BD Vacutainer CPT™. Additionally, blood from a finger prick was collected on isocode cards from each patient. MtDNA was extracted from whole blood using a QiaAmp DNA MiniKit (Qiagen). NAF was recovered by a qualified practitioner, using a FIRSTCYTE™ Aspirator (Cytyc Health Corporation) following the recommendations of the manufacturer, and stored in CytoLyt Solution until extracted. Using this device, NAF was expressed from 1–3 ducts and pooled for the study. This method of NAF collection is therefore not representative of the entire ductal system, and could miss ducts with lesions. For diagnostic purposes, a better method of NAF collection is needed. The total volume of NAF collected per patient ranged from 50 – 100 μL. MtDNA was extracted using the QiaAmp DNA MiniKit (Qiagen) and archived at -86°C. Both NAF and blood isolated mtDNA samples were randomized and blinded for the cross-lab validation.
Mitochondrial genome amplification
Method used at Genesis Genomics Inc
The entire mtgenome of both NAF and corresponding blood samples were amplified using a single back-to-back primer set or three overlapping primers (see primer sequences in Table 1). These primers were designed using proprietary software that precludes pseudogene coamplification. 25 ng of template DNA, 5U LA Taq polymerase (TaKara), 5 μL buffer, 2.5 mM each of dNTPs, 0.2 μM of primers were mixed with dH20 to a final reaction volume of 50 μL. Cycling parameters were as follows: 94°C for 1 min, followed by 35 cycles of 94°C for 10s, 68°C for 15 min, 72°C for 10 min, and a final hold at 4°C.
Method used at NIST
DNA amplification was performed independently at NIST using three primer pairs previously used for fluorescent DNA sequencing resulting in 3 amplicons of 5–6 kb in length for full coverage of the mitochondrial genome [26]. Samples which did not amplify using these primers were successfully amplified using the nine primer sets previously validated for full mtDNA fluorescent sequencing [2]. Each PCR product was visualized on an agarose gel to obtain a qualitative assessment of the amount of mtDNA generated by the procedure. The mitochondrial DNA template, 10 μmol of primers, 0.5U LA Taq polymerase (TaKara), 5 μL buffer, 8 μL dNTPs (10 μmol each) and 33 μL of dH20 were mixed for a total reaction volume of 50 μL. Thermal cycling conditions were as follows: 94°C for 2 min, followed by 30 cycles of 94°C for 15 s, 68°C for 7 min; final elongation 68°C for 12 min; 4°C hold. PCR amplification products were analyzed for quality and quantity as previously [2] or by spectrophotometric methods as described in GeneChip CustomSeq™ Resequencing Array Protocol Version 2.
PCR Cleanup: MitoChip
PCR clean up was conducted using the QIAquick 96 well vacuum plate manifold and protocol (Qiagen). DNAs were eluted into 65 uL of DNAse/RNAse free water.
CE-based Fluorescent Sequencing
Amplified mtgenome template was sent to CoGenics (Houston, Texas) for capillary electrophoresis sequencing. Briefly, Big Dye Termination Chemistry and a series of 72 primers were used to sequence in both forward and reverse directions. The fluorescent PCR-based sequencing was also conducted independently as a cross validation at NIST using previously published reaction conditions [2]. Primers contained M13 tags to facilitate DNA sequencing with M13 forward and reverse sequences. Briefly, the blood and NAF mtDNAs were sequenced using the Big Dye™ Terminator (BDT) version 3.1 cycle sequencing kit (ABI). A one eighth cycle sequencing reaction was used for each primer. Reactions contained 1 μL of each of the following reagents: BDT reagent, DNA (3–6 ng/μL), M13 primer (forward or reverse; 5 pmol/μL), 5× Dilution Buffer (ABI), and dH2O to a final volume of 5 μL. Cycling sequencing conditions for forward primers were as follows: (40 cycles): 96°C for 10 s; annealing, 50°C for 5 s; elongation, 60°C for 4 min; 4°C hold. Reverse primers were sequenced using the same protocol, but the annealing temperature was lowered to 37°C.
The Montage™ SEQ96 plate (Millipore Corp., Billerica, MA) was used for clean-up following the cycle sequencing reactions. Thirty microliters of Wash Solution was added to each well of the cycle sequencing plate. The samples were transferred to the clean-up plate and placed on the vacuum manifold for 15–20 minutes or until the wells were dry. A second wash of 30 μL Wash Solution was added and vacuumed dry for an additional 25 to 30 minutes. Once dry, 20 μL of Injection Solution were added to each well and the plate was mixed vigorously on a plate shaker for 10 minutes. Resuspended samples were transferred to a 3100 Optical Plate and diluted with 15 μL of HI-DI Formamide (ABI). All separations were performed using the ABI 3130×LGenetic Analyzer with an 80 cm capillary and POP7 polymer system. Samples were electrokinetically injected (30 seconds, 1 KV) and separated at 14.6 KV. Sequences were aligned using the DNA Star SeqMan II (5.05) program and scanned for polymorphisms and sequence variants in direct comparison to revised Cambridge Reference Sequence (rCRS) and the corresponding sequence of the blood.
Resequencing: MitoChip protocol
The GeneChip® CustomSeq® Resquencing Array Protocol Version 2 was used with a few modifications. Following amplification of the mtgenome, template was prepared and hybridized as recommended by the GeneChip® Resequencing Reagent Kit. MCv2 chips were processed in the GeneChip® Hybridization Oven 640, GeneChip® Fluidics Station 450 and the GeneChip® Scanner 3000. Briefly, either three or nine amplicons representing the patient and normal control mitochondrial genomes were separately pooled at equi-molar concentrations. The PCR amplification products were pooled, fragmented, labeled, hybridized, washed, and scanned. The total quantity of DNA applied to the array was 0.62 μg. Fragmentation of the pooled DNAs was conducted using 0.15 units of Fragmentation reagent (0.033 μL) per sample at 37°Cfor 15 minutes followed by 95°C for 15 minutes to inactivate. The fragments were labeled with 30 units of TdT at 37°C for 90 minutes followed by 95°C for 15 minutes. The hybridization cocktail, including separately prepared control fragments, was hybridized for 16 to 18 hours at 45°C with 60 rpm. Arrays were washed using the mini_mapping10kv1_450 fluidics protocol, scanned on a GeneArray® 2500 Scanner or a GeneChip® Scanner 3000G7 Scanner, and analyzed with GeneChip® DNA analysis (GDAS) and GSEQ Softwares.
MitoChip Sequence Interpretation
Final analysis of all data was conducted using Affymetrix software GCOS v1.4 and GSEQ v4.0. The probe intensities for each mutation reported by the software were examined on the forward and reverse strands for every occurrence of a specific base position located on the chip. Mutations were confirmed and only reported when the mutation was seen on both strands for locations appearing once, and 3 of 4 strands for locations that appear on the chip twice. We selected a random subset of our patient samples (3 tissues each from 4 patients) to evaluate the accuracy of the MitoChip in comparison to CE DNA sequencing. All samples were blinded and phylogenetic trees were returned using the PHYLIP program Dnaml, Dnapars and Dnadist [27].
Short Tandem Repeat (STR) Genotyping
All samples were genotyped using the PowerPlex® 16 System (Promega Corp, Madison, WI) on a 3130×L genetic analyzer with a 36 cm capillary array and POP4 polymer and analyzed using GeneMapper® ID v3.2 (Applied Biosystems, Foster City, CA (ABI). Samples were diluted to 0.5 – 1.0 ng/μL and 1 μL of sample was added to a 24 μL reaction volume (18.2 μL H2O, 2.5 μL 10× buffer, 2.5 μL PowerPlex® 16 10× primer pair mix, 0.8 μL (4U) AmpliTaq Gold® DNA Polymerase (ABI), then PCR amplified using published conditions. 1 μL of ILS600 internal lane standard and 9 μL of HiDi™ Formamide (ABI) were added to 1 μL of reaction (or 1 μL Allelic Ladder Mix, one for each run) then the mix was briefly denatured and chilled to 95°C and then placed on crushed ice for 3 minutes prior to each sequencing run.
Results and Discussion
Quality assurance
STR typing was performed on all samples to eliminate the possibility of inadvertent sample mix-up or cross contamination.
Sequencing of whole mtgenome from NAF samples
Two previous studies have examined mtDNA mutations in NAF, however, both studies examined less than 30% of the mtgenome [18, 19]. For diagnostic purposes, it is more informative to interrogate the complete mtgenome. Hence, our attempt was to reliably sequence the complete mtgenome from NAF. NAF was successfully extracted from 23 of the 28 women recruited for this study. Twenty two (96%) of the women produced NAF from both breasts, and 20 NAF samples from the left breasts and matched blood were chosen for this study. Table 2 shows the clinicopathologic and demographic data of the study participants. Overall thirty-nine (20 blood and 19 NAF) samples were successfully processed; one NAF sample could not be fully amplified and was not included in the analysis. The entire mtgenome of 14 out of 19 NAF samples were successfully amplified using a single full length primer pair, with the remaining 5 samples requiring three overlapping primers. Although the primers were designed to preclude pseudogene co-amplification, the ability to amplify the full length mtgenome in biological samples such as NAF with reduced cellularity is an added quality assurance measure against pseudogenes. Sequence comparison between the NAF, blood and rCRS revealed a total of 490 polymorphisms and 7 mutations. Of the 7 mutations (SNPs discovered only in the NAF and not present in the blood) noted between all samples, three were associated with known problematic features of MCv2 at nucleotide positions 9179, 9914, and 11719 (Table 3). Comparison of MCv2 sequence data to the gold standard (CE) revealed a 99.999% identity. These results indicate that microarray resequencing of the mtgenome recovered from NAF is a rapid, sensitive and cost effective technique. Importantly, this technology enables clinical access to the information content of the mtgenome of mammary ductal epithelial cells.
Cross validation of MCv2
The ability to rapidly sequence the mtgenome from NAF was cross-lab validated by independent confirmation at separate venues with a 99.200% concordance. Table 3 records the comparative data between the work done at NIST and Genesis Genomics, demonstrating repeatability of the detection method and consensus on the number of mtDNA mutations. Maximum likelihood clustering analysis of the blinded results from both labs demonstrates general clustering from the suite of samples from any given subject (Figure 1), again demonstrating the accuracy of the data obtained at each institution. Moreover, each individual was resolved into mitochondrial haplogroups, as expected. Haplogroup polymorphisms were accurately detected in both NAF and blood samples from the respective participant. In general, this study population was essentially of European ancestry. Although Figure 1 appears to indicate differences between the NAF and blood samples from a given patient, this effect is an artifact since the genetic distances between these samples is very small (e.g. 0.00001). These small distances are also true for the general outline of the tree.
Elevated somatic mtDNA mutations in benign breast disease
Four out of 19 (21%) NAF samples contained a single point mutation difference from the matched controls (blood) (Table 4). Previous work on partial mtgenome analysis is consistent with our results [18]. This work by Zhu et al. reported that some mutations detected in NAF were also found in the patient's primary tumor, emphasizing the possible utility of NAF for breast cancer screening. Although no tumor was detected in our cohort of women, these mutations may indicate mtgenome instability, perhaps suggesting an elevated risk for breast cancer in these 4 women. For example, patient 1069 had a C/T heteroplasmy at bp 516, which is within a D-Loop region of known mtgenome instability in breast tumors [28]. Heteroplasmy is considered an early marker of potential disease [29, 30]. Moreover, one study concluded that breast tumors that have mutations within the D-Loop have less favorable patient outcomes than those lacking these alterations [31]. Thus this simple, sensitive measurement of the mutation load from non-invasively collected samples, offers an alternative for diagnostic purposes.
One important aspect of this project is the massive amount of genetic data collected in a relatively short period. Close to 1.6 × 106 mtgenome bases were sequenced, demonstrating an extremely fine genetic resolution when using the MCv2. This suggests that cross-validated point mutations may indeed be important indicators of altered molecular processes indicative of potential transformation. Independent cross-validation confirmed these mutations. Combined with the broad resolution demonstrated by the blinded Maximum likelihood clustering results, in association with corresponding demographic data, this technology is capable of gathering a broad spectrum of population level data. Moreover, this methodology may have important utility in the early detection of breast cancer associated mutations in NAF.
Conclusion
Ductal lavage and random periareolar fine needle aspiration are both used to harvest breast epithelial cells for risk assessment as well as to evaluate response in chemoprevention trials. The magnitude of increase in relative risk has been defined and other studies have concluded that presence of NAF with epithelial cells is associated with an increase in breast cancer risk and that such cells harbor useful markers for women at higher risk [32]. However, the evaluation of NAF has shown limited promise in part, because of poor cytologic reproducibility [33]. The measurement of cancer associated mutations in the entire mtgenome may overcome such limitations.
Resequencing with microarray technology is a rapid, highly accurate, relatively inexpensive method, which enables the widespread investigation of mitochondrial mutations detected in non-invasively collected body fluids associated with solid tumors. The cost saving benefits of chip-based sequencing techniques, including reagents, labor, time-to-results, ease and accuracy of data interpretation, are substantial in comparison to typical fluorescent sequencing methods. For example, 12 mtgenomes can be sequenced with a chip per day, as opposed to 12 mtgenomes per month, using a 16 capillary DNA sequencer, a 30-fold increase in productivity and data acquisition. This demonstrates potential, important utility from a disease detection perspective. Finally, the chip can detect low-level heteroplasmy, a condition often associated with the genesis of disease.
Abbreviations
- NAF:
-
nipple aspirate fluid
- MCv2:
-
MitoChip v2.0
- CE:
-
capillary electrophoresis
- mtDNA:
-
mitochondrial DNA.
References
Jakupciak JP: Analysis of potential cancer biomarkers in mitochondrial DNA. Current Opinion in Molecular Therapeutics. 2006, 8: 500-5006.
Jakupciak JP, Wang W, Markowitz ME, Ally D, Coble M, Srivastava S, Maitra A, Barker PE, Sidransky D, O'Connell C D: Mitochondrial DNA as a cancer biomarker. J Mol Diagn. 2005, 7: 258-267.
Fliss MS, Usadel H, Caballero OL, Wu L, Buta MR, Eleff SM, Jen J, Sidransky D: Facile detection of mitochondrial DNA mutations in tumors and bodily fluids. Science. 2000, 287: 2017-2019. 10.1126/science.287.5460.2017.
Polyak K, Li Y, Zhu H, Lengauer C, Willson JK, Markowitz SD, Trush MA, Kinzler KW, Vogelstein B: Somatic mutations of the mitochondrial genome in human colorectal tumours. Nat Genet. 1998, 20: 291-293. 10.1038/3108.
Jeronimo C, Nomoto S, Caballero OL, Usadel H, Henrique R, Varzim G, Oliveira J, Lopes C, Fliss MS, Sidransky D: Mitochondrial mutations in early stage prostate cancer and bodily fluids. Oncogene. 2001, 20: 5195-5198. 10.1038/sj.onc.1204646.
Zhou S, Kachhap S, Sun W, Wu G, Chuang A, Poeta L, Grumbine L, Mithani SK, Chatterjee A, Koch W, Westra WH, Maitra A, Glazer C, Carducci M, Sidransky D, McFate T, Verma A, Califano JA: Frequency and phenotypic implications of mitochondrial DNA mutations in human squamous cell cancers of the head and neck. Proc Natl Acad Sci U S A. 2007, 104: 7540-7545. 10.1073/pnas.0610818104.
Jacobs L, Gerards M, Chinnery P, Dumoulin J, de Coo I, Geraedts J, Smeets H: mtDNA point mutations are present at various levels of heteroplasmy in human oocytes. Mol Hum Reprod. 2007, 13: 149-154. 10.1093/molehr/gal112.
Sauter ER, Wagner-Mann C, Ehya H, Klein-Szanto A: Biologic markers of breast cancer in nipple aspirate fluid and nipple discharge are associated with clinical findings. Cancer Detect Prev. 2007, 31: 50-58. 10.1016/j.cdp.2006.12.004.
King BL, Love SM: The intraductal approach to the breast: raison d'etre. Breast Cancer Res. 2006, 8: 206-10.1186/bcr1410.
Dooley WC, Ljung BM, Veronesi U, Cazzaniga M, Elledge RM, O'Shaughnessy JA, Kuerer HM, Hung DT, Khan SA, Phillips RF, Ganz PA, Euhus DM, Esserman LJ, Haffty BG, King BL, Kelley MC, Anderson MM, Schmit PJ, Clark RR, Kass FC, Anderson BO, Troyan SL, Arias RD, Quiring JN, Love SM, Page DL, King EB: Ductal lavage for detection of cellular atypia in women at high risk for breast cancer. J Natl Cancer Inst. 2001, 93: 1624-1632.
Wrensch MR, Petrakis NL, Gruenke LD, Ernster VL, Miike R, King EB, Hauck WW: Factors associated with obtaining nipple aspirate fluid: analysis of 1428 women and literature review. Breast Cancer Res Treat. 1990, 15: 39-51. 10.1007/BF01811888.
Krishnamurthy S, Sneige N, Thompson PA, Marcy SM, Singletary SE, Cristofanilli M, Hunt KK, Kuerer HM: Nipple aspirate fluid cytology in breast carcinoma. Cancer. 2003, 99: 97-104. 10.1002/cncr.10958.
Sharma P, Klemp JR, Simonsen M, Welsko CM, Zalles CM, Kimler BF, Fabian CJ: Failure of high risk women to produce nipple aspirate fluid does not exclude detection of cytologic atypia in random periareolar fine needle aspiration specimens. Breast Cancer Res Treat. 2004, 87: 59-64. 10.1023/B:BREA.0000041582.11586.d3.
Mitchell G, Trott PA, Morris L, Coleman N, Sauter E, Eeles RA: Cellular characteristics of nipple aspiration fluid during the menstrual cycle in healthy premenopausal women. Cytopathology. 2001, 12: 184-196. 10.1046/j.1365-2303.2001.00313.x.
Higgins SA, Matloff ET, Rimm DL, Dziura J, Haffty BG, King BL: Patterns of reduced nipple aspirate fluid production and ductal lavage cellularity in women at high risk for breast cancer. Breast Cancer Res. 2005, 7: R1017-22. 10.1186/bcr1335.
Wrensch M, Petrakis NL, King EB, Lee MM, Miike R: Breast cancer risk associated with abnormal cytology in nipple aspirates of breast fluid and prior history of breast biopsy. Am J Epidemiol. 1993, 137: 829-833.
Wrensch MR, Petrakis NL, Miike R, King EB, Chew K, Neuhaus J, Lee MM, Rhys M: Breast cancer risk in women with abnormal cytology in nipple aspirates of breast fluid. J Natl Cancer Inst. 2001, 93: 1791-1798. 10.1093/jnci/93.23.1791.
Zhu W, Qin W, Bradley P, Wessel A, Puckett CL, Sauter ER: Mitochondrial DNA mutations in breast cancer tissue and in matched nipple aspirate fluid. Carcinogenesis. 2005, 26: 145-152. 10.1093/carcin/bgh282.
Isaacs C, Cavalli LR, Cohen Y, Pennanen M, Shankar LK, Freedman M, Singh B, Liu M, Gallagher A, Rone JD, Dickson RB, Sidransky D, Haddad BR: Detection of LOH and mitochondrial DNA alterations in ductal lavage and nipple aspirate fluids from hngh-risk patients. Breast Cancer Res Treat. 2004, 84: 99-105. 10.1023/B:BREA.0000018406.03679.2e.
Maki J, Robinson K, Reguly B, Alexander J, Wittock R, Aguirre A, Diamandis EP, Escott N, Skehan A, Prowse O, Thayer RE, Froberg MK, Wilson MJ, Maragh S, Jakupciak JP, Wagner PD, Srivastava S, Dakubo GD, Parr RL: Mitochondrial genome deletion aids in the identification of false- and true-negative prostate needle core biopsy specimens. Am J Clin Pathol. 2008, 129: 57-66. 10.1309/UJJTH4HFEPWAQ78Q.
He J, Gornbein J, Shen D, Lu M, Rovai LE, Shau H, Katz J, Whitelegge JP, Faull KF, Chang HR: Detection of breast cancer biomarkers in nipple aspirate fluid by SELDI-TOF and their identification by combined liquid chromatography-tandem mass spectrometry. Int J Oncol. 2007, 30: 145-154.
Khan SA, Wiley EL, Rodriguez N, Baird C, Ramakrishnan R, Nayar R, Bryk M, Bethke KB, Staradub VL, Wolfman J, Rademaker A, Ljung BM, Morrow M: Ductal lavage findings in women with known breast cancer undergoing mastectomy. J Natl Cancer Inst. 2004, 96: 1510-1517.
Jones JB, Song JJ, Hempen PM, Parmigiani G, Hruban RH, Kern SE: Detection of mitochondrial DNA mutations in pancreatic cancer offers a "mass"-ive advantage over detection of nuclear DNA mutations. Cancer Res. 2001, 61: 1299-1304.
Dakubo GD: Mitochondrial genome analysis in biofluids for early cancer detection and monitoring. Expert Opin Med Diagn. 2008, 2: 263-275. 10.1517/17530059.2.3.263.
van Eijsden RG, Gerards M, Eijssen LM, Hendrickx AT, Jongbloed RJ, Wokke JH, Hintzen RQ, Rubio-Gozalbo ME, De Coo IF, Briem E, Tiranti V, Smeets HJ: Chip-based mtDNA mutation screening enables fast and reliable genetic diagnosis of OXPHOS patients. Genet Med. 2006, 8: 620-627.
Maitra A, Cohen Y, Gillespie SE, Mambo E, Fukushima N, Hoque MO, Shah N, Goggins M, Califano J, Sidransky D, Chakravarti A: The Human MitoChip: a high-throughput sequencing microarray for mitochondrial mutation detection. Genome Res. 2004, 14: 812-819. 10.1101/gr.2228504.
Felsenstein J: PHYLIP - Phylogeny Inference Package (Version 3.2). Cladistics. 1989, 5:
Richard SM, Bailliet G, Paez GL, Bianchi MS, Peltomaki P, Bianchi NO: Nuclear and mitochondrial genome instability in human breast cancer. Cancer Res. 2000, 60: 4231-4237.
Penta JS, Johnson FM, Wachsman JT, Copeland WC: Mitochondrial DNA in human malignancy. Mutat Res. 2001, 488: 119-133. 10.1016/S1383-5742(01)00053-9.
Legros F, Malka F, Frachon P, Lombes A, Rojo M: Organization and dynamics of human mitochondrial DNA. J Cell Sci. 2004, 117: 2653-2662. 10.1242/jcs.01134.
Tseng LM, Yin PH, Chi CW, Hsu CY, Wu CW, Lee LM, Wei YH, Lee HC: Mitochondrial DNA mutations and mitochondrial DNA depletion in breast cancer. Genes Chromosomes Cancer. 2006, 45: 629-638. 10.1002/gcc.20326.
Buehring GC, Letscher A, McGirr KM, Khandhar S, Che LH, Nguyen CT, Hackett AJ: Presence of epithelial cells in nipple aspirate fluid is associated with subsequent breast cancer: a 25-year prospective study. Breast Cancer Res Treat. 2006, 98: 63-70. 10.1007/s10549-005-9132-5.
Visvanathan K, Santor D, Ali SZ, Brewster A, Arnold A, Armstrong DK, Davidson NE, Helzlsouer KJ: The reliability of nipple aspirate and ductal lavage in women at increased risk for breast cancer--a potential tool for breast cancer risk assessment and biomarker evaluation. Cancer Epidemiol Biomarkers Prev. 2007, 16: 950-955. 10.1158/1055-9965.EPI-06-0974.
Pre-publication history
The pre-publication history for this paper can be accessed here:http://www.biomedcentral.com/1471-2407/8/95/prepub
Acknowledgements
We thank the patients and their physicians for participation in this study. Financial support for this project was provided to Genesis Genomics Inc. by Industry Canada (FedNor), and Northern Ontario Heritage Fund Corporation (NOHFC). This study was also funded by interagency agreement Y1CN5001-01 between the US National Institute of Standards and Technology (NIST) and the National Cancer Institute's Early Detection Research Network (EDRN).
Disclaimer
Certain commercial equipment, instruments, materials or companies are identified in this paper to specify adequately the experimental procedure. Such identification does not imply recommendation nor endorsement by the National Institute of Standards and Technology, nor does it imply that the materials or equipment identified are the best available for the purpose.
Author information
Authors and Affiliations
Corresponding author
Additional information
Competing interests
The author(s) declare that they have no competing interests.
Authors' contributions
AM, SM, JM, and KR conducted experiments and helped analyze the data. BR performed sequence analysis. RW coordinated sample collection. KG and TG collected NAF samples. PW and SS helped in data analysis and preparation of the manuscript. AN performed sequence analysis and generated the Maximum likelihood tree. RET, GDD, JPJ and RLP coordinated and supervised the research, and wrote the manuscript.
Authors’ original submitted files for images
Below are the links to the authors’ original submitted files for images.
Rights and permissions
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
About this article
Cite this article
Jakupciak, J.P., Maggrah, A., Maragh, S. et al. Facile whole mitochondrial genome resequencing from nipple aspirate fluid using MitoChip v2.0. BMC Cancer 8, 95 (2008). https://doi.org/10.1186/1471-2407-8-95
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/1471-2407-8-95