Skip to main content

Table 5 Dosimetric parameters for organs at risk with each planning technique

From: Ninety-degree angled collimator: a dosimetric study related to dynamic intensity-modulated radiotherapy in patients with endometrial carcinoma

 

Mean ± SD

(minimum–maximum)

Global

P

 

C-IMRT

A-IMRT

VMAT

 

Bone marrow V40 (%)

47.00 ± 6.94a

(33.21–56.52)

47.79 ± 7.53a

(33.90–58.12)

35.14 ± 2.33b

(29.99–40.33)

0.000 *

Bladder V45 (%)

44.21 ± 6.67a

(30.15–55.47)

32.84 ± 2.03b

(28.62–34.88)

25.59 ± 4.72c

(19.58–34.17)

0.000 *

Rectum V30 (%)

73.80 ± 4.75a

(63.64–80.62)

56.18 ± 2.05b

(52.16–59.77)

49.37 ± 4.82c

(38.96–58.06)

0.000 *

Bowel V35 (%)

30.83 ± 9.68a

(13.41–45.44)

31.27 ± 9.77a

(14.85–47.57)

27.62 ± 8.17b

(10.38–39.47)

0.000 *

Bowel V40 (%)

26.10 ± 8.93a

(9.11–38.14)

25.76 ± 8.56a,b

(10.11–39.46)

22.06 ± 6.92b

(6.51–31.24)

0.000 *

Right femoral head V30 (%)

21.42 ± 4.03a

(15.39–27.62)

12.19 ± 1.34b

(10.33–14.87)

8.71 ± 2.41b

(4.71–13.30)

0.000 *

Left femoral head V30 (%)

21.35 ± 4.16a

(15.20–31.32)

12.58 ± 1.48b

(9.29–14.85)

8.79 ± 2.39c

(5.61–14.84)

0.000 *

Normal tissue (cGy)

1981 ± 423a

(849–2532)

1966 ± 416a

(855–2509)

1799 ± 355b

(785–2235)

0.000 *

  1. Abbreviations: C-IMRT = 0° angled collimated dynamic IMRT planning technique; A-IMRT = 90° angled collimated dynamic IMRT planning technique; VMAT = volumetric modulated arc therapy; a,b or c = in the comparison between two groups, if the groups have the same letter, there is no statistically significant difference, but if the same letter is not found, there is a statistically significant difference; (*) means statistically significant = p < 0.05; V30 = volume receiving ≥ 30 Gy of the prescribed dose; V35 = volume receiving ≥ 35 Gy of the prescribed dose; V40 = volume receiving ≥ 40 Gy of the prescribed dose; V45 = volume receiving ≥ 45 Gy of the prescribed dose; SD = standard deviation