Skip to main content

Table 2 Description of the methodology used to assess the biomarker concentration

From: Blood serum proteins as biomarkers for prediction of survival, locoregional control and distant metastasis rate in radiotherapy and radio-chemotherapy for non-small cell lung cancer

Marker

Test name

Company

Method

Material /storage

Measurement units

OPN

Quantikine ELISA Human Osteopontin (OPN)

R&D Systems

ELISA

plasma/−80 °C/

ng/ml

VEGF

RayBio Human VEGF ELISA Kit

RayBiotech,Inc.

ELISA

serum/−80 °C

pg/ml

EPO

Immulite 2000 EPO

Siemens

chemiluminescence

serum/−80 °C

mIU/ml

HMGB1

HMGB1 ELISA

IBL International GMBH

ELISA

serum/−80 °C

ng/ml

IGF1

IGF-I ELISA

DRGInstruments GmbH

ELISA

serum/−80 °C

ng/ml

PDGF

RayBio Human PDGF-BB ELISA Kit

RayBiotech,Inc.

ELISA

serum/−80 °C

pg/ml