Skip to main content

Table 1 Values of Blood Perfusion, Thermal Conductivity and Metabolic Heat Production [9–11]

From: Computer simulation in conjunction with medical thermography as an adjunct tool for early detection of breast cancer

Layers

(cbwb)1

(cbwb)2

(cbwb)3

k

qm

 

W m-3 °C-1

W m-3 °C-1

W m-3 °C-1

W m-3 °C-1

W m-3

Areola

800

1600

800

0.21

400

Lower-inner Subcutaneous

800

1600

800

0.21

400

Lower-outer Subcutaneous

800

1600

800

0.21

400

Upper-outer Subcutaneous

800

1600

800

0.21

400

Upper-inner Subcutaneous

800

1600

800

0.21

400

Lower-inner Gland

2400

2400

2400

0.48

700

Lower-outer Gland

2400

2400

2400

0.48

700

Upper-outer Gland

2400

2400

3600

0.48

700

Upper-inner Gland

2400

2400

2400

0.48

700

Gland Core (All 4 Volumes)

2400

2400

2400

0.48

700

Muscle Core

2400

2400

2400

0.48

700

Tumour (32 mm)

48 × 103

48 × 103

48 × 103

0.48

5.5 × 103