Skip to main content

Table 2 Comparison of dosimetric parameters of panned target volume (CTV) before and after seed implantation of 25 patients with refractory malignant tumor

From: Evaluation of radioactive 125I seed implantation for the treatment of refractory malignant tumours based on a CT-guided 3D template-assisted technique: efficacy and safety

Parameters

Before surgery

After surgery

P

Interval

Median

Interval

Median

Interval

Median

D90

114–181

148

145.32 ± 23.48

105–180

128

142.16 ± 22.25

0.39

V100

76.6–100

96.3

94.63 ± 5.76

73.7–100

95

93.47 ± 6.29

0.33

V150

46.2–90.4

64.5

67.35 ± 14.07

46.7–89.6

66.1

66.72 ± 12.11

0.23

CI

0.4–0.8

0.66

0.63 ± 0.11

0.42–0.82

0.61

0.63 ± 0.11

0.42

EI

0.18–1.1

0.42

0.46 ± 0.27

0.21–1.3

0.46

0.50 ± 0.29

0.38

HI

0.09–0.61

0.31

0.31 ± 0.13

0.1–0.59

0.34

0.31–0.12

0.40