Skip to main content

Table 5 Confusion matrix for PH2 dataset

From: An implementation of normal distribution based segmentation and entropy controlled features selection for skin lesion detection and classification

Confusion Matrix: Proposed features fusion and selection

 

Class

Tested images

Melanoma

Benign

Caricinoma

Melanoma

20

92.5%

7.5%

 

Benign

40

2.5%

97.5%

 

Caricinoma

40

  

100%

Confusion matrix: Harlick features

 

Class

Total Images

Melanoma

Benign

Caricinoma

Melanoma

20

57.5%

35%

7.5%

Benign

40

8.8%

68.8%

22.5%

Caricinoma

40

3.8%

13.8%

82.5%

Confusion matrix: HOG features

 

Class

Total Images

Melanoma

Benign

Caricinoma

Melanoma

20

70%

30%

-

Benign

40

10%

88.8%

1.3%

Caricinoma

40

-

-

100%

Confusion matrix: Color features

 

Class

Total Images

Melanoma

Benign

Caricinoma

Melanoma

20

95%

5.0%

-

Benign

40

3.8%

95%

1.3%

Caricinoma

40

1.3%

5.0%

93.8%