Skip to main content

Table 2 Results obtained from samples of the round robin test. Reference values were obtained from the trial coordinators by a multiplex assay analyzed on a capillary sequencer and reported to our laboratory. Afterwards, the samples were re-analyzed on the QiaXcel Advanced system. All samples could be fully confirmed by analyzing the peak patterns

From: Microsatellite instability testing in colorectal cancer using the QiaXcel advanced platform

Round Robin Sample

BAT25

BAT26

D5s346

D2S123

D17s250

MS-status

1

expected

wt

wt

wt

wt

wt

MSS/MSI-L

our result

wt

wt

wt

wt

wt

MSS

2

expected

MSI

MSI

MSI

MSI

MSI

MSI-H

our result

MSI

MSI

MSI

MSI

MSI

MSI-H

3

expected

wt

wt

wt

wt

wt

MSS/MSI-L

our result

wt

wt

wt

wt

wt

MSS

4

expected

MSI

MSI

MSI

MSI

MSI

MSI-H

our result

MSI

MSI

MSI

MSI

MSI

MSI-H

5

expected

wt

wt

wt

wt

wt

MSS/MSI-L

our result

wt

wt

wt

wt

wt

MSS

6

expected

wt

wt

wt

wt

wt

MSS/MSI-L

our result

wt

wt

wt

wt

wt

MSS

7

expected

MSI

MSI

MSI

MSI

MSI

MSI-H

our result

MSI

MSI

MSI

MSI

MSI

MSI-H

8

expected

MSI

MSI

MSI

MSI

MSI

MSI-H

our result

MSI

MSI

MSI

MSI

MSI

MSI-H